Search results for "Functional acuity contrast test"

showing 2 items of 2 documents

Diseño de una nueva prueba para medir la función de sensibilidad al contraste con iPad

2015

[EN] Purpose: To introduce a new application (ClinicCSF) to measure Contrast Sensitivity Function (CSF) with tablet devices, and to compare it against the Functional Acuity Contrast Test (FACT). Methods: A total of 42 subjects were arranged in two groups of 21 individuals. Different versions of the ClinicCSF (.v1 and .v2) were used to measure the CSF of each group with the same iPad and the results were compared with those measured with the FACT. The agreements between ClinicCSF and FACT for spatial frequencies of 3, 6, 12 and 18 cycles per degree (cpd) were represented by Bland---Altman plots. Results: Statistically significant differences in CSF of both groups were found due to the change…

AdultMalemedia_common.quotation_subjectVision DisordersVisual performanceFACTDesempeño visualCycles per degreeContrast SensitivityYoung Adultlcsh:OphthalmologyStatisticsHumansContrast (vision)lcsh:QC350-467Tablet devicesDiagnosis Computer-AssistedSensitivity (control systems)Simulationmedia_commonContrast sensitivity functionDispositivos de tabletaVision TestsMiddle AgedFunctional acuity contrast testConfidence intervalTest (assessment)Función de sensibilidad al contrasteiPadlcsh:RE1-994Computers HandheldFISICA APLICADAOriginal ArticleFemaleSpatial frequencyPsychologyEFAClcsh:Optics. LightOptometry
researchProduct

Visual acuity and contrast sensitivity screening with a new iPad application

2016

We present a new iPad application (app) for a fast assessment of Visual Acuity (VA) and Contrast Sensitivity (CS) whose reliability and agreement was evaluated versus a commercial screening device (Optec 6500). The measurement of VA was programmed in the app in accordance with the Amblyopia Treatment Study protocol. The CS was measured with sinusoidal gratings of four different spatial frequencies: 3, 6, 12 and 18 cpd at the same contrast values of the Functional Acuity Contrast Test (FACT) included in the Optec 6500. Forty-five healthy subjects with monocular corrected visual acuities better than 0.2 logMAR participated in the agreement study. Bland-Altman analyses were performed to assess…

medicine.medical_specialtyVisual acuityVisual acuitygenetic structuresComputer sciencemedia_common.quotation_subject01 natural sciences010104 statistics & probability03 medical and health sciences0302 clinical medicineOphthalmologymedicineContrast (vision)Computer visionContrast sensitivity0101 mathematicsElectrical and Electronic Engineeringmedia_commonbusiness.industryLimits of agreementHealthy subjectsFunctional acuity contrast testHuman-Computer InteractioniPadHardware and ArchitectureTreatment studyFISICA APLICADA030221 ophthalmology & optometryScreeningSpatial frequencyArtificial intelligencemedicine.symptombusinessSensitivity (electronics)
researchProduct